Share
Add to compare

PBT TAROLOX 10 Taro Plast S.p.A.

Product Description
Certificates(0)
Datasheet

Product Description

Certificates

No Data...

Technical Data Sheet

impact performanceTest ConditionTest MethodTest ResultTest Unit
Charpy Notched Impact Strength23°CISO 1796.0kJ/m²
Impact strength of cantilever beam gap-20°C,3.20mmASTMD25630J/m
Impact strength of cantilever beam gap23°C,3.20mmASTMD25650J/m
flammabilityTest ConditionTest MethodTest ResultTest Unit
UL flame retardant rating1.6mmUL 94HB
Hot filament ignition temperature2.0mmIEC 60695-2-13750°C
Extreme Oxygen IndexASTM D286322%
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
bending strengthBreakASTM D79070.0MPa
bending strengthYieldASTM D79080.0MPa
bending strength--3ISO 17880.0MPa
bending strength--2ISO 17870.0MPa
Bending modulusASTMD7902300MPa
elongationBreakASTMD638>100%
tensile strengthBreakASTMD63850.0MPa
tensile strengthYieldASTMD63855.0MPa
Tensile modulusASTMD6382500MPa
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Vicat softening temperature--ASTMD152510180°C
Linear coefficient of thermal expansionMD:-30to30°CASTM D6961E-04cm/cm/°C
Melting temperatureASTMD211220to225°C
Ball Pressure Test165°CVDE0470通过
Vicat softening temperature--ASTMD15259200°C
Hot deformation temperature0.45MPa,UnannealedASTMD648160°C
Hot deformation temperature1.8MPa,UnannealedASTMD64860.0°C
Continuous use temperature--5IEC 6021690.0°C
Continuous use temperature--6IEC 60216120°C
Continuous use temperature--7IEC 60216130°C
Continuous use temperature--8IEC 60216160°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
GranuleHumidityInternal Method<0.050%
Water absorption rateSaturation,23°CISO 620.50%
Water absorption rateSaturationASTM D5700.50%
Water absorption rate23°C,24hrASTMD5700.080%
Shrinkage rateTDASTM D9551.6to1.8%
Shrinkage rateMDASTM D9551.6to1.8%
melt mass-flow rate250°C/1.2kgASTMD123820g/10min
densityASTMD7921.30to1.32g/cm³
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Compared to the anti leakage trace indexSolutionAIEC 60112PLC 0
Dielectric strength2.00mmASTM D14918kV/mm
Volume resistivityASTM D257>1.0E+15ohms·cm
Compared to the anti leakage trace indexSolutionBIEC 60112PLC 2
hardnessTest ConditionTest MethodTest ResultTest Unit
Rockwell hardnessR-ScaleASTM D785120
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.