Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ISO 1183 | 1.09 g/cm³ |
melt mass-flow rate | | ASTM D1238 | 40 g/10min |
melt mass-flow rate | | ISO 1133 | 40 g/10min |
Shrinkage rate | | ASTM D955 | 0.40to0.70 % |
density | | ASTM D792 | 1.09 g/cm³ |
hardness | Test Condition | Test Method | Test Result |
---|
Rockwell hardness | R-Scale | ASTM D785 | 95 |
Rockwell hardness | R-Scale | ISO 2039-2 | 95 |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL 94 | HB |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ISO 180/1A | 40 kJ/m² |
Impact strength of cantilever beam gap | | ASTM D256 | 390 J/m |
Impact strength of cantilever beam gap | | ASTM D256 | 200 J/m |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ASTM D638 | 1800 MPa |
Tensile modulus | | ISO 527-2/50 | 2000 MPa |
tensile strength | Yield | ASTM D638 | 43.0 MPa |
tensile strength | Yield | ISO 527-2/50 | 43.0 MPa |
tensile strength | Break | ASTM D638 | 26.0 MPa |
tensile strength | Break | ISO 527-2/50 | 31.0 MPa |
elongation | Break | ASTM D638 | 17 % |
Tensile strain | Break | ISO 527-2/50 | 11 % |
Flexural modulus | | ASTM D790 | 1700 MPa |
Flexural modulus | | ISO 178 | 1760 MPa |
bending strength | | ASTM D790 | 49.0 MPa |
bending strength | | ISO 178 | 49.0 MPa |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ISO 75-2/A | 73.0 °C |
Heat distortion temperature | | ISO 75-2/A | 89.0 °C |
vicat | | ISO 306/B50 | 90.0 °C |
vicat | | ISO 306/B120 | 94.0 °C |
Heat distortion temperature | | ASTM D648 | 95.0 °C |
Heat distortion temperature | | ISO 75-2/B | 85.0 °C |
Heat distortion temperature | | ISO 75-2/B | 97.0 °C |
Heat distortion temperature | | ASTM D648 | 80.0 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.