POM KL-4030 SABIC INNOVATIVE US
72
Form:Granules | Grade:Injection grade
Properties:
Low extractwear resistant
Typical Applications:
Plastic bagMedical and nursing supplies
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Plastic bag | Medical and nursing supplies |
| Properties: | Low extract | wear resistant |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | 23°C | ISO 180/1A | 3.0 | kJ/m² |
| Suspended wall beam without notch impact strength | 23°C | ISO 180/1U | 46 | kJ/m² |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | ASTM D638 | 2530 | Mpa | |
| ISO 527-2/1 | 2460 | Mpa | ||
| tensile strength | Yield | ASTM D638 | 48.0 | Mpa |
| Yield | ISO 527-2/5 | 46.0 | Mpa | |
| Break | ASTM D638 | 48.0 | Mpa | |
| Break | ISO 527-2/5 | 46.0 | Mpa | |
| elongation | Yield | ASTM D638 | 10 | % |
| Tensile strain | Yield | ISO 527-2/5 | 9.0 | % |
| elongation | Break | ASTM D638 | 19 | % |
| Tensile strain | Break | ISO 527-2/5 | 16 | % |
| Bending modulus | 50.0mmSpan | ASTM D790 | 2210 | Mpa |
| ISO 178 | 2250 | Mpa | ||
| bending strength | ASTM D790 | 75.8 | Mpa | |
| Friction coefficient | Dynamic | ASTM D3702Modified | 0.35 | |
| Static | ASTM D3702Modified | 0.17 | ||
| Wear factor | Ring | ASTM D3702Modified | 0.300 | 10^-10in^5-min/ft-lb-hr |
| Washer | ASTM D3702Modified | 11.0 | 10^-10in^5-min/ft-lb-hr | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45MPa,Unannealed,3.20mm | ASTM D648 | 158 | °C |
| 0.45MPa,Unannealed,64.0mmSpan | ISO 75-2/Bf | 149 | °C | |
| 1.8MPa,Unannealed,3.20mm | ASTM D648 | 97.0 | °C | |
| 1.8MPa,Unannealed,64.0mmSpan | ISO 75-2/Af | 88.0 | °C | |
| Linear coefficient of thermal expansion | MD:-30to30°C | ASTM D696 | 1.1E-04 | cm/cm/°C |
| TD:-30to30°C | ASTM D696 | 1.1E-04 | cm/cm/°C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | 0.29 | % |
| Shrinkage rate | MD:24hr | ASTM D955 | 1.0-3.0 | % |
| TD:24hr | ASTM D955 | 1.0-3.0 | % | |
| Water absorption rate | 24hr,50%RH | ASTM D570 | 0.20 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.