Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | 内部方法 | 1.22 g/cm³ |
hardness | Test Condition | Test Method | Test Result |
---|
Shore hardness | | ISO 868 | 80 |
ball-indentation hardness | | ISO 2039-1 | 98.0 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Suspended wall beam without notch impact strength | | ISO 180/1U | 21 kJ/m² |
Charpy Notched Impact Strength | | ISO 179/1eA | 5.4 kJ/m² |
Impact strength of simply supported beam without notch | | ISO 179/1eU | 35 kJ/m² |
Impact strength of cantilever beam gap | | ISO 180/1A | 4.2 kJ/m² |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ISO 527-2 | 3200 MPa |
Tensile modulus | | ISO 527-2 | 2500 MPa |
tensile strength | | ISO 527-2 | 51.0 MPa |
tensile strength | | ISO 527-2 | 47.0 MPa |
Tensile strain | | ISO 527-2 | 9.0 % |
Tensile strain | | ISO 527-2 | 5.5 % |
Flexural modulus | | ISO 178 | 2900 MPa |
bending strength | | ISO 178 | 73.0 MPa |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ISO 75-2/B | 157 °C |
Heat distortion temperature | | ISO 75-2/A | 96.0 °C |
vicat | | ISO 306/A50 | 179 °C |
vicat | | ISO 306/B50 | 166 °C |
melting temperature | | ISO 11357 | 176 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.