Share
Add to compare

PA66 Staramide ACF6 EUROSTAR FRANCE

Properties:
Filler carbon fiber reinforced material 30% filler by weight
Product Description
Certificates(0)
Datasheet

Product Description

Properties:Filler | carbon fiber reinforced material | 30% | filler by weight

Certificates

No Data...

Technical Data Sheet

impact performanceTest ConditionTest MethodTest ResultTest Unit
Impact strength of simply supported beam without notch23°CISO 179/1eU70kJ/m²
Impact strength of cantilever beam gap-40°CISO 180/1A6.0kJ/m²
Impact strength of cantilever beam gap-20°CISO 180/1A7.0kJ/m²
Impact strength of cantilever beam gap23°CISO 180/1A8.0kJ/m²
flammabilityTest ConditionTest MethodTest ResultTest Unit
UL flame retardant rating1.6mmUL 94HB
Extreme Oxygen IndexISO 4589-227%
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Tensile modulusISO 527-2/122000MPa
tensile strengthBreakISO 527-2/5250MPa
Tensile strainBreakISO 527-2/52.0%
Bending modulusISO 17819500MPa
bending strengthISO 178360MPa
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Hot deformation temperature0.45MPa,Unannealed,100mmSpanISO 75-2/Be260°C
Hot deformation temperature1.8MPa,Unannealed,100mmSpanISO 75-2/Ae257°C
Vicat softening temperatureISO 306/B120255°C
Linear coefficient of thermal expansionMD:23to60°CISO 11359-21.4E-05cm/cm/°C
Linear coefficient of thermal expansionTD:23to60°CISO 11359-21E-04cm/cm/°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
Water absorption rateSaturation,23°CISO 624.5%
densityISO 11831.27g/cm³
Shrinkage rateMDInternal Method0.040to0.080%
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Surface resistivityIEC 600934.3E+03ohms
Volume resistivityIEC 600934.3E+03ohms·cm
hardnessTest ConditionTest MethodTest ResultTest Unit
Rockwell hardnessL-SaleISO 2039-2108
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.