Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Water absorption rate | | ISO 62 | 1.2 % |
Water absorption rate | | ISO 62 | 2.4 % |
density | | ISO 1183 | 1.14 g/cm³ |
Shrinkage rate | | ISO 294-4 | 2.0 % |
Shrinkage rate | | ISO 294-4 | 2.2 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ISO 180/1A | 5.0 kJ/m² |
tensile strength | | ISO 527-2 | 85 MPa |
tensile strength | | ISO 527-2 | 55 MPa |
elongation at break | | ISO 527-2 | 5.0 % |
elongation at break | | ISO 527-2 | 25 % |
Tensile modulus | | ISO 527-2 | 3100 MPa |
Tensile modulus | | ISO 527-2 | 0.40 |
bending strength | | ISO 178 | 95 MPa |
Flexural modulus | | ISO 178 | 2900 MPa |
Charpy Notched Impact Strength | | ISO 179/1eA | 6.0 kJ/m² |
Charpy Notched Impact Strength | | ISO 179/1eA | 5.0 kJ/m² |
Impact strength of simply supported beam without notch | | ISO 179/1eU | NB kJ/m² |
Impact strength of simply supported beam without notch | | ISO 179/1eU | NB kJ/m² |
Impact strength of cantilever beam gap | | ISO 180/1A | 6.0 kJ/m² |
Flame retardant performance | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL -94 | V-2 0.71mm |
UL flame retardant rating | | UL -94 | V-2 1.50mm |
UL flame retardant rating | | UL -94 | V-2 3.00mm |
Limiting Oxygen Index | | ISO 4589-2 | 23 % |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Dissipation Factor | | IEC 61621 | 60-119 s |
Dissipation Factor | | IEC 60112 | 400-599 V |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Hot deformation temperature (HDT) | | ISO 75-2/Bf | 200 °C |
Hot deformation temperature (HDT) | | ISO 75-2/Af | 70 °C |
| | ISO 11359-2 | 1E-05 cm/cm/°C |
| | ISO 11359-2 | 1E-05 cm/cm/°C |
linear expansion coefficient | | ISO 11359-2 | 260 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.