Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTM D792 | 0.910 g/cm³ |
Water absorption rate | | ASTM D570 | <0.010 % |
Water absorption rate | Saturation | ASTM D570 | <0.010 % |
hardness | Test Condition | Test Method | Test Result |
---|
Shore hardness | | ASTM D2240 | 78 |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL 94 | HB |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
tensile strength | Ultimate | ASTM D638 | 33.1 MPa |
elongation | Break | ASTM D638 | 12 % |
Flexural modulus | | ASTM D790 | 1240 MPa |
bending strength | Yield | ASTM D790 | 33.1 MPa |
Compression Modulus | | ASTM D695 | 1380 MPa |
compressive strength | | ASTM D695 | 34.5 MPa |
coefficient of friction | Steel - Static | 内部方法 | 0.25 |
Tensile modulus | | ASTM D638 | 1190 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ASTM D256A | 110 J/m |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Surface Resistivity | | ASTM D257 | >1.0E+15 ohms |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ASTM D648 | 98.9 °C |
Maximum operating temperature LongTerm, Air | | | 82 °C |
Crystallization peak temperature | | ASTM D3418 | 160 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.