Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Shrinkage rate | | ASTM D-955 | 0.4(0.8) % |
Basic performance | Test Condition | Test Method | Test Result |
---|
Water absorption rate | | ASTM D-570 | 0.3(3.0) % |
Other performance | Test Condition | Test Method | Test Result |
---|
Glass Fiber Content | | | 30 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
elongation | | ASTM D-638 | 4(3) % |
bending strength | | ASTM D-790 | 240(200) Mpa |
Rockwell hardness | | ASTM D-785 | 95 M Scale |
Flexural modulus | | ASTM D-790 | 11000(8000) Mpa |
Impact strength of cantilever beam gap | | ASTM D-256 | 80(90) J/m |
tensile strength | | ASTM D-638 | 160(140) Mpa |
Electrical performance | Test Condition | Test Method | Test Result |
---|
dielectric strength | | ASTM D-149 | 25 KV/mm |
Dissipation Factor | | ASTM D-150 | 25 |
dielectric constant | | ASTM D-150 | 4.0 |
Volume resistivity | | ASTM D-257 | 10 Ω.cm |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Glass transition temperature (Tg) | | | 85 °C |
Linear coefficient of thermal expansion | | ASTM D-696 | 3.0(6.0) |
UL flame retardant rating | | UL 94 | V-0 |
melting temperature | | | 310 °C |
Heat distortion temperature | | ASTM D-648 | 290 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.