plas
Log In

PBI CELAZOLE®  U-60SD PBI USA

4

Technical Data Sheet

impact performanceTest ConditionTest MethodTest Result
Suspended wall beam without notch impact strengthASTM D256590 J/m
flammabilityTest ConditionTest MethodTest Result
Extreme Oxygen IndexASTM D286358 %
mechanical propertiesTest ConditionTest MethodTest Result
Bending modulusASTM D7906550 Mpa
elongationBreakASTM D6383.0 %
tensile strengthASTM D638159 Mpa
Tensile modulusASTM D6385860 Mpa
Friction coefficient与金属-静态40.16
Friction coefficient与金属-静态30.14
Friction coefficient与金属-动态40.18
Friction coefficient与金属-动态30.16
Friction coefficientSteel - Static0.15
Friction coefficientSteel - Dynamic0.16
compressive strength10%StrainASTM D695345 Mpa
compressive strength--2ASTM D695393 Mpa
Compressive modulusASTM D6955860 Mpa
bending strengthASTM D790221 Mpa
Fatigue-%ofstresstofailureASTM D63835 %
thermal performanceTest ConditionTest MethodTest Result
Hot deformation temperature1.8MPa,UnannealedASTM D648435 °C
Glass transition temperatureDMA427 °C
Linear coefficient of thermal expansionMD:24to149°CTMA2.3E-05 cm/cm/°C
Linear coefficient of thermal expansionMD:199to299°CTMA3.2E-05 cm/cm/°C
Linear coefficient of thermal expansionMD:导热系数(25°C)TMA0.40 W/m/K
Physical propertiesTest ConditionTest MethodTest Result
Water absorption rate23°C,24hrASTM D5700.40 %
Electrical performanceTest ConditionTest MethodTest Result
Arc resistanceASTM D495185 sec
Dissipation factor100kHzASTM D1500.034
Dissipation factor10kHzASTM D1503E-03
Dissipation factor1kHzASTM D1500.0
Dielectric constant100kHzASTM D1503.30
Dielectric constant10kHzASTM D1503.40
Dielectric constant1kHzASTM D1503.40
Volume resistivityASTM D2572E+15 ohms·cm
Dielectric strengthASTM D14923 KV/mm
hardnessTest ConditionTest MethodTest Result
Shore hardnessShoreDASTM D224095
Rockwell hardnessM-ScaleASTM D785>125
Rockwell hardnessE-SaleASTM D785104
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.