PPA HTN51G45HSL DUPONT USA
30
Form:Granules | Grade:Injection grade
Properties:
High impact resistanceLow temperature resistancHigh temperature resistanFiller: Glass fiber reinf45% filler by weight
Typical Applications:
Automotive interior parts
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Automotive interior parts |
| Properties: | High impact resistance | Low temperature resistanc | High temperature resistan | Filler: Glass fiber reinf | 45% filler by weight |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of simply supported beam without notch | 23℃ | kJ/m² | 4.178to19.964 | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| Burning wire flammability index | °C | 743to960 | ||
| Extreme Oxygen Index | % | 23to25 | ||
| Hot filament ignition temperature | °C | 721to926 | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | 摩擦系数 | 0.15to0.52 | ||
| Yield, 23 ℃ | 68.97to250.34 | MPa | ||
| Fracture, 23 ℃ | 131.72to400.0 | MPa | ||
| % | 1.0to2.5 | |||
| % | 1.5to3.1 | |||
| Yield, 23 ℃ | % | 1.4to2.5 | ||
| compressive strength | 23℃ | 142.76to196.55 | MPa | |
| Poisson's ratio | 23℃ | 0.41 | ||
| Yield, 23 ℃ | 102.76to362.76 | MPa | ||
| shear strength | 23℃ | 88.28to107.59 | MPa | |
| Fracture, 23 ℃ | 162.76to199.31 | MPa | ||
| Yield, 23 ℃ | % | 1.5to2.6 | ||
| 12.62to270.34 | MPa | |||
| Fracture, 23 ℃ | 108.28to262.76 | MPa | ||
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| flow | mm/mm/°C | 185.4E-5-25.4E-5 | ||
| 1.8MPa, unannealed | °C | 249to304 | ||
| flow | mm/mm/°C | 38.1E-5-50.8E-5 | ||
| RTI Elec | °C | 140to150 | ||
| RTI Imp | °C | 118to150 | ||
| 0.45MPa, unannealed | °C | 273to312 | ||
| transverse | mm/mm/°C | 63.5E-5-177.8E-5 | ||
| 1.8MPa, annealed | °C | 283to300 | ||
| transverse | mm/mm/°C | 68.6E-5-127.0E-5 | ||
| flow | mm/mm/°C | 195.6E-5-25.4E-5 | ||
| Vicat softening temperature | °C | 258to313 | ||
| 8.0Mpa, unannealed | °C | 165to230 | ||
| 1.8MPa, unannealed | °C | 247to292 | ||
| 0.45MPa, annealed | °C | 296to320 | ||
| 0.45MPa, unannealed | °C | 275to308 | ||
| RTI | °C | 119to150 | ||
| Continuous use temperature | °C | 140to186 | ||
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Flow: 23 ℃ | Flow,23℃ | mm/mm | 48.3E-3-129.5E-3 | |
| 23℃,24hr | % | 0.12to0.30 | ||
| Lateral flow: 23 ℃ | Across Flow, 23℃ | mm/mm | 119.4E-3-0.254 | |
| Balance, 23 ℃, 50% RH | % | 0.21to1.2 | ||
| 23℃,24hr | % | 0.30to0.51 | ||
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the anti leakage trace index | V | |||
| CTI | V | |||
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | 23℃ | 125 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.