PA66 Vydyne® 20NSP BLK

0

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
densityISO 11831.14 g/cm³
Shrinkage rateISO 294-41.6 %
Shrinkage rateISO 294-41.4 %
Outdoor applicabilityUL 746Cf2
Water absorption rateISO 621.2 %
Water absorption rateISO 622.4 %
flammabilityTest ConditionTest MethodTest Result
Burning wire flammability indexIEC 60695-2-12960 °C
Burning wire flammability indexIEC 60695-2-12960 °C
Burning wire flammability indexIEC 60695-2-12960 °C
Hot filament ignition temperatureIEC 60695-2-13825 °C
Hot filament ignition temperatureIEC 60695-2-13850 °C
Hot filament ignition temperatureIEC 60695-2-13850 °C
Hot filament ignition temperatureIEC 60695-2-13850 °C
Limiting Oxygen IndexISO 4589-226 %
UL flame retardant ratingUL 94V-2
UL flame retardant ratingUL 94V-2
UL flame retardant ratingUL 94V-2
UL flame retardant ratingUL 94V-2
Burning wire flammability indexIEC 60695-2-12960 °C
Mechanical propertiesTest ConditionTest MethodTest Result
Tensile strainISO 527-25.0 %
Nominal tensile fracture strainISO 527-213 %
Flexural modulusISO 1783200 MPa
bending strengthISO 178100 MPa
Poisson's ratioISO 527-20.40
Tensile modulusISO 527-23800 MPa
tensile strength ISO 527-295.0 MPa
tensile strength ISO 527-275.0 MPa
Impact resistanceTest ConditionTest MethodTest Result
Charpy Notched Impact StrengthISO 179/1eA6.0 kJ/m²
Impact strength of simply supported beam without notchISO 179/1eUNoBreak
Impact strength of simply supported beam without notchISO 179/1eUNoBreak
Impact strength of cantilever beam gapISO 1805.0 kJ/m²
Impact strength of cantilever beam gapISO 1806.0 kJ/m²
Charpy Notched Impact StrengthISO 179/1eA5.0 kJ/m²
Electrical performanceTest ConditionTest MethodTest Result
Volume resistivityIEC 600931E+13 ohms·cm
dielectric strengthIEC 6024326 kV/mm
arc resistanceASTM D495PLC 5
Compared to the Leakage Tracking Index (CTI)IEC 60112PLC 0
High arc combustion index (HAI)UL 746PLC 1
High arc combustion index (HAI)UL 746PLC 0
High arc combustion index (HAI)UL 746PLC 0
High arc combustion index (HAI)UL 746PLC 0
High Voltage Arc Traceability Rate (HVTR)UL 746PLC 0
Hot wire ignition (HWI)UL 746PLC 4
Hot wire ignition (HWI)UL 746PLC 4
Hot wire ignition (HWI)UL 746PLC 3
Hot wire ignition (HWI)UL 746PLC 2
Thermal performanceTest ConditionTest MethodTest Result
Hot deformation temperature (HDT)ISO 75-2/B230 °C
Hot deformation temperature (HDT)ISO 75-2/A90.0 °C
RTI ElecUL 746130 °C
RTI ElecUL 746130 °C
RTI ElecUL 746130 °C
RTI ImpUL 74675.0 °C
RTI ImpUL 74675.0 °C
RTI ImpUL 74675.0 °C
RTI ImpUL 74675.0 °C
RTI StrUL 74675.0 °C
RTI StrUL 74685.0 °C
RTI StrUL 74685.0 °C
RTI StrUL 74685.0 °C
melting temperatureISO 11357-3260 °C
ISO 11359-21E-04 cm/cm/°C
ISO 11359-21E-04 cm/cm/°C
RTI ElecUL 746130 °C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.

Contact Us

Get App

Top