LCP E473i BK210P TAIWAN POLYPLASTICS
55
Form:Granules | Grade:Extrusion grade
Properties:
enhanceGlass fiber reinforced
Typical Applications:
Electrical applicationsHome appliance components
Product Description
Certificates(1)
Datasheet
Product Description
| Typical Applications: | Electrical applications | Home appliance components |
| Properties: | enhance | Glass fiber reinforced |
Certificates
Technical Data Sheet
| flammability | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| UL flame retardant rating | UL 94 | V-0 | ||
| Color number | VF2201/BK210P | |||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| tensile strength | ASTM D638 | 125 | Mpa | |
| elongation | Break | ASTM D638 | 2.8 | % |
| Bending modulus | ISO 178 | 11000 | Mpa | |
| bending strength | ISO 178 | 160 | Mpa | |
| Bending strain | ISO 178 | 2.8 | % | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45 MPa, Unannealed | ISO 75-2/B | 275 | °C |
| 1.8 MPa, Unannealed | ISO 75-2/A | 250 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | 横向Flow : 1.00 mm | Internal Method | 0.39 | % |
| Flow : 1.00 mm | Internal Method | 0.030 | % | |
| Water absorption rate | 24 hr, 23°C | ISO 62 | 0.020 | % |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | IEC 60093 | 1.0E+16 | ohms·cm | |
| Dielectric strength | 1.00 mm | IEC 60243-1 | 53 | KV/mm |
| 3.00 mm | IEC 60243-1 | 26 | KV/mm | |
| Relative permittivity | 1 kHz | IEC 60250 | 4.20 | |
| 1 MHz | IEC 60250 | 3.70 | ||
| Dissipation factor | 1 kHz | IEC 60250 | 0.020 | |
| 1 MHz | IEC 60250 | 0.030 | ||
| Arc resistance | ASTM D495 | 151 | sec | |
| Compared to the anti leakage trace index | IEC 60112 | V | ||
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | M -Sale | ISO 2039-2 | 55 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.