Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
density | ASTM D-792 | 1.16 | |
melt mass-flow rate | ASTM D-1238 | 180 g/10min | |
Shrinkage rate | ASTM D-955 | 0.4-0.7 % | |
Water absorption rate | ASTM D-570 | 0.3 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
tensile strength | ASTM D-638 | 33 kg/cm2 | |
Rockwell hardness | ASTM D-785 | 102 R | |
Flexural modulus | ASTM D-790 | 22000 kg/cm2 | |
Impact strength of cantilever beam gap | ASTM D-256 | 11.0 kg.cm/cm | |
bending strength | ASTM D-790 | 600 kg/cm2 | |
elongation | ASTM D-638 | 55 % |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
dielectric strength | ASTM D-149 | 540↑ v/mil | |
dielectric constant | ASTM D-150 | 2.8↓ 107Cvl/s | |
Volume resistivity | ASTM D-257 | 1016↑ Ω.cm |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
vicat | ASTM D-1525 | 92 ℃ | |
Heat distortion temperature | ASTM D-648 | 76 ℃ | |
ASTM D-648 | 88 ℃ |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.