impact performanceTest ConditionTest MethodTest Result
Charpy Notched Impact StrengthISO 179/1eA4.0 kJ/m²
flammabilityTest ConditionTest MethodTest Result
UL flame retardant rating6.0mmUL 94V-0
UL flame retardant rating3.0mmUL 94V-0
mechanical propertiesTest ConditionTest MethodTest Result
Tensile modulusISO 527-23100 MPa
tensile strengthYieldISO 527-2110 MPa
Tensile strainBreakISO 527-212 %
thermal performanceTest ConditionTest MethodTest Result
thermal conductivityDIN 526120.24 W/m/K
specific heatDIN 526121100 J/kg/°C
Hot deformation temperature1.8MPa,UnannealedISO 75-2/A200 °C
Usage temperatureLongTerm-50-170 °C
Usage temperatureShortTerm<210 °C
Physical propertiesTest ConditionTest MethodTest Result
densityISO 11831.27 g/cm³
Water absorption rateEquilibrium,23°C,50%RHISO 620.50 %
Electrical performanceTest ConditionTest MethodTest Result
Surface resistivityIEC 600931E+15 ohms
Volume resistivityIEC 600931E+17 ohms·cm
Dielectric strengthIEC 60243-130 kV/mm
Dielectric constant100HzIEC 602503.20
Dissipation factor100HzIEC 602501.5E-03
Compared to the anti leakage trace indexSolutionAIEC 60112PLC 4
hardnessTest ConditionTest MethodTest Result
Shore hardnessShoreDDIN 5350586
Ball Pressure TestISO 2039-1220 MPa
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.