| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | 1.60mm | ASTM D256 | 530 | J/m |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 1.6mm | UL 94 | HB | |
| Extreme Oxygen Index | 1.60mm | ASTM D2863 | 22 | % |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| tensile strength | 1.60mm | ASTM D638 | 72.4 | MPa |
| compressive strength | 1.60mm | ASTM D695 | 96.5 | MPa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| RTI Elec | 0.71mm | UL 746 | 190 | °C |
| 1.5mm | UL 746 | 200 | °C | |
| RTI | 0.71mm | UL 746 | 190 | °C |
| 1.5mm | UL 746 | 200 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ASTM D792 | 1.60 | g/cm³ | |
| Water absorption rate | 24hr | ASTM D570 | 1.1 | % |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Arc resistance | 1.60mm | ASTM D495 | 139 | sec |
| Compared to the anti leakage trace index | 1.60mm | UL 746 | PLC 1 | |
| High arc combustion index | 1.60mm | UL 746 | PLC 0 | |
| Hot wire ignition | 0.711mm | UL 746 | PLC 2 | sec |
| 1.47mm | UL 746 | PLC 1 | sec | |
| Dielectric strength | 1.60mm,PerpendicularS/TinAir | ASTM D149 | 18 | kV/mm |
| 1.60mm,PerpendicularS/TinOil | ASTM D149 | 22 | kV/mm | |
| Dielectric constant | 1.60mm,60Hz | ASTM D150 | 6.40 | |
| 1.60mm,1MHz | ASTM D150 | 4.20 | ||
| Dissipation factor | 1.60mm,60Hz | ASTM D150 | 0.070 | |
| 1.60mm,1MHz | ASTM D150 | 0.033 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.