Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Mold shrinkage rate | | ASTM D-955 | 0.5~0.7 % |
other | Test Condition | Test Method | Test Result |
---|
notes | | | 模具收缩率:0.5~0.7 |
| | | 标准,高粘度。 电气、电子产品制造(电子连接器,照明灯具,齿轮,风扇,照相机外壳,钻头机架,灯具外壳等)。 |
Basic performance | Test Condition | Test Method | Test Result |
---|
Water absorption rate | | ASTM D-570 | 0.15 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
bending strength | | ASTM D-790 | 900 kg/cm |
elongation | | ASTM D-638 | 150 % |
Rockwell hardness | | ASTM D-785 | 120 R scale |
Flexural modulus | | ASTM D-790 | 20000 kg/cm |
IZOD impact strength | | ASTM D-256 | 80 kg·cm/cm |
tensile strength | | ASTM D-638 | 700 kg/cm |
elongation at break | | ASTM D638/ISO 527 | 150 % |
tensile strength | | ASTM D638/ISO 527 | 700 kg/cm²(MPa)[Lb/in²] |
Rockwell hardness | | ASTM D785 | 120 |
Flexural modulus | | ASTM D790/ISO 178 | 20000 kg/cm²(MPa)[Lb/in²] |
bending strength | | ASTM D790/ISO 178 | 900 kg/cm²(MPa)[Lb/in²] |
Electrical performance | Test Condition | Test Method | Test Result |
---|
ARC resistance | | ASTM D-495 | 120 sec |
Loss factor | | ASTM D-150 | 0.0092 |
Conductivity | | ASTM D-150 | 2.85 |
dielectric strength | | ASTM D-149 | 30 KV/mm |
Volume resistivity | | ASTM D-257 | 4 Ω.cm |
Volume resistivity | | ASTM D257/IEC 60093 | 4x10^16 Ω.cm |
Physical properties | Test Condition | Test Method | Test Result |
---|
density | | ASTM D792/ISO 1183 | 1.2 |
Water absorption rate | | ASTM D570/ISO 62 | 0.15 % |
Thermal performance | Test Condition | Test Method | Test Result |
---|
| | ASTM D-648 | 147 °C |
| | ASTM D-696 | 5.6×10 mm/mm/℃ |
| | ASTM D-648 | 136 °C |
Combustibility (rate) | | UL94 | HB |
| | ASTM D648/ISO 75 | 136 ℃(℉) |
Linear expansion coefficient | | ASTM D696/ISO 11359 | 5.6×10^-5 mm/mm.℃ |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.