Share
Add to compare

PPS DIC.PPS FZ-3600 DIC Corporation

Properties:
Filler glass mineral
Typical Applications:
General
Product Description
Certificates(0)
Datasheet

Product Description

Typical Applications:General
Properties:Filler | glass mineral

Certificates

No Data...

Technical Data Sheet

impact performanceTest ConditionTest MethodTest ResultTest Unit
Impact strength of cantilever beam gapASTM D25670J/m
Suspended wall beam without notch impact strengthASTM D256260J/m
flammabilityTest ConditionTest MethodTest ResultTest Unit
UL flame retardant rating0.8mmUL 94V-0
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Friction coefficientSteel - StaticASTM D18940.35
Elongation at BreakASTM D7901.3%
Tensile modulusASTM D63818500MPa
tensile strengthASTM D638125MPa
elongationBreakASTM D6380.80%
Bending modulusASTM D79017500MPa
bending strengthASTM D790200MPa
compressive strengthASTM D695150MPa
Poisson's ratio0.34
Friction coefficientSteel - DynamicASTM D18940.35
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Hot deformation temperature1.8MPa,UnannealedASTM D648265°C
Linear coefficient of thermal expansionMD:-30to90°CASTM D6961.7E-05cm/cm/°C
Linear coefficient of thermal expansionTD:-30to90°CASTM D6961.7E-05cm/cm/°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
densityASTM D7921.96g/cm³
Shrinkage rateMDASTM D9550.25%
Shrinkage rateTDASTM D9551.0%
Water absorption rate23°C,24hrASTM D5700.020%
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Volume resistivityASTM D2571E+16ohms·cm
Dielectric strength1.60mmASTM D14916kV/mm
Dielectric constant1MHzASTM D1505.00
Dissipation factor1MHzASTM D1507E-03
Arc resistanceASTM D495180sec
Compared to the anti leakage trace indexASTM D3638PLC 2
hardnessTest ConditionTest MethodTest ResultTest Unit
Rockwell hardnessM-ScaleASTM D785100
Rockwell hardnessR-ScaleASTM D785121
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.