PSU R-5500 SOLVAY USA
144
Form:Granules | Grade:Injection grade
Properties:
heat-resistingChemical resistance
Typical Applications:
Industrial componentsElectrical applicationsVehicle electronics
Product Description
Certificates(1)
Datasheet
Product Description
| Typical Applications: | Industrial components | Electrical applications | Vehicle electronics |
| Properties: | heat-resisting | Chemical resistance |
Certificates

Technical Data Sheet
| optical performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Refractive index | ASTM D542 | 1.672 | ||
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
| Impact strength of cantilever beam gap | 3.18mm | ASTM D1822 | 399 | kJ/m² |
| 3.18mm | ASTM D256 | 690 | J/m | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 0.76mm | UL 94 | V-0 | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Bending modulus | 3.18mm | ASTM D790 | 2410 | Mpa |
| elongation | Break,3.18mm | ASTM D638 | 60to120 | % |
| Yield,3.18mm | ASTM D638 | 7.2 | % | |
| tensile strength | 3.18mm | ASTM D638 | 69.6 | Mpa |
| Tensile modulus | 3.18mm | ASTM D638 | 2340 | Mpa |
| bending strength | 5.0%Strain,3.18mm | ASTM D790 | 91.0 | Mpa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Linear coefficient of thermal expansion | MD:3.18mm | ASTM D696 | 5.6E-05 | cm/cm/°C |
| Glass transition temperature | ASTME1356 | 220 | °C | |
| Hot deformation temperature | 1.8MPa,Unannealed,3.18mm | ASTM D648 | 207 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | Equilibrium | ASTM D570 | 1.1 | % |
| 24hr | ASTM D570 | 0.37 | % | |
| Shrinkage rate | MD:3.18mm | ASTM D955 | 0.70 | % |
| melt mass-flow rate | 365°C/5.0kg | ASTM D1238 | 12to17 | g/10min |
| density | ASTM D792 | 1.29 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dielectric constant | 3.18mm,60Hz | ASTM D150 | 3.44 | |
| Dielectric strength | 3.18mm | ASTM D149 | 15 | KV/mm |
| 0.0254mm | ASTM D149 | >200 | KV/mm | |
| Volume resistivity | ASTM D257 | 9E+15 | ohms·cm | |
| Supplementary Information | Test Condition | Test Method | Test Result | Test Unit |
| Steam disinfection - containing morpholine | >1000 | cycles |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.