PA6 K224-G6-FC BK00001 DSM Additive Manufacturing

0
  • Properties:
    Filler
    glass fiber reinforced material
    30%
    filler by weight

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
densityISO 11831.35 g/cm³
Shrinkage rateISO 294-40.90 %
Shrinkage rateISO 294-40.30 %
Water absorption rateISO 626.3 %
Water absorption rateISO 621.9 %
Impact resistanceTest ConditionTest MethodTest Result
Charpy Notched Impact StrengthISO 179/1eA11 kJ/m²
Charpy Notched Impact StrengthISO 179/1eA12 kJ/m²
Impact strength of simply supported beam without notchISO 179/1eU75 kJ/m²
Impact strength of simply supported beam without notchISO 179/1eU90 kJ/m²
Mechanical propertiesTest ConditionTest MethodTest Result
Tensile modulusISO 527-29500 MPa
tensile strength BreakISO 527-2180 MPa
Tensile strainBreakISO 527-23.5 %
Flexural modulusISO 1788600 MPa
bending strengthISO 178235 MPa
Electrical performanceTest ConditionTest MethodTest Result
Dissipation FactorIEC 602505E-03
Dissipation FactorIEC 602500.015
Compared to the Leakage Tracking Index (CTI)IEC 60112 V
Surface ResistivityIEC 60093-- ohms
Volume resistivityIEC 600931E+15 ohms·cm
dielectric strengthIEC 60243-130 kV/mm
relative permittivityIEC 602503.50
relative permittivityIEC 602503.30
Thermal performanceTest ConditionTest MethodTest Result
Heat distortion temperatureISO 75-2/B220 °C
Heat distortion temperatureISO 75-2/A200 °C
melting temperatureISO 11357-3220 °C
Linear coefficient of thermal expansionISO 11359-22E-05 cm/cm/°C
Linear coefficient of thermal expansionISO 11359-27E-05 cm/cm/°C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.

Contact Us

Get App

Top