PA HiFill® TPX-HTN-03002 A

0
  • Properties:
    Filler
    Techmer
    American Techmer

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
densityASTMD7921.49 g/cm³
Shrinkage rateASTMD9550.70 %
Shrinkage rateASTMD9550.70 %
Water absorption rateASTMD5700.19 %
flammabilityTest ConditionTest MethodTest Result
UL flame retardant ratingUL94HB
Mechanical propertiesTest ConditionTest MethodTest Result
elongationBreakASTMD6382.8 %
Flexural modulusASTMD790689 MPa
bending strengthASTMD790172 MPa
tensile strengthASTMD63889.6 MPa
Impact resistanceTest ConditionTest MethodTest Result
Impact strength of cantilever beam gapASTMD25648 J/m
Electrical performanceTest ConditionTest MethodTest Result
Volume resistivityASTMD2578E+15 ohms·cm
dielectric strengthASTMD14924 kV/mm
Thermal performanceTest ConditionTest MethodTest Result
ASTMD648302 °C
ASTMD6963.4E-05 cm/cm/°C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.

Contact Us

Get App

Top