POM 127UV DUPONT USA
49
Form:Granules | Grade:Injection grade
Properties:
High temperature resistanFlame retardantenhance
Typical Applications:
Medical supplies
Product Description
Certificates(1)
Datasheet
Product Description
| Typical Applications: | Medical supplies |
| Properties: | High temperature resistan | Flame retardant | enhance |
Certificates
UL
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | 23°C | ISO 180/1A | 13 | kJ/m² |
| Charpy Notched Impact Strength | -30°C | ISO 179/1eA | 11 | kJ/m² |
| 23°C | ISO 179/1eA | 15 | kJ/m² | |
| Impact strength of simply supported beam without notch | -30°C | ISO 179/1eU | 350 | kJ/m² |
| 23°C | ISO 179/1eU | 400 | kJ/m² | |
| Impact strength of cantilever beam gap | -40°C | ISO 180/1A | 11 | kJ/m² |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| Burning rate | 1.00mm | ISO 3795 | 28 | mm/min |
| UL flame retardant rating | 0.8mm | UL 94 | HB | |
| 0.8mm | IEC 60695-11-10,-20 | HB | ||
| FMVSS flammability | FMVSS302 | B | ||
| Fogging-G-value | condensate | ISO 6452 | 1.5E-04 | g |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | ISO 527-2 | 3000 | Mpa | |
| tensile strength | Yield | ISO 527-2 | 70.0 | Mpa |
| Tensile strain | Yield | ISO 527-2 | 23 | % |
| Nominal tensile fracture strain | ISO 527-2 | 45 | % | |
| Bending modulus | ISO 178 | 2700 | Mpa | |
| bending strength | 3.5%Strain | ISO 178 | 80.5 | Mpa |
| -- | ISO 178 | 72.0 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| AnnealingTime-Optional | 30.0 | min/mm | ||
| Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/B | 160 | °C |
| 1.8MPa,Unannealed | ISO 75-2/A | 93.0 | °C | |
| Vicat softening temperature | ISO 306/B50 | 160 | °C | |
| Melting temperature | ISO 11357-3 | 178 | °C | |
| Linear coefficient of thermal expansion | MD | ISO 11359-2 | 1.2E-04 | cm/cm/°C |
| TD | ISO 11359-2 | 1.1E-04 | cm/cm/°C | |
| AnnealingTemperature | 160 | °C | ||
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ISO 1183 | 1.42 | g/cm³ | |
| melt mass-flow rate | 190°C/2.16kg | ISO 1133 | 2.4 | g/10min |
| Melt Volume Flow Rate (MVR) | 190°C/2.16kg | ISO 1133 | 1.90 | cm3/10min |
| Shrinkage rate | TD | ISO 294-4 | 1.9 | % |
| MD | ISO 294-4 | 2.1 | % | |
| Water absorption rate | 23°C,24hr | ISO 62 | 0.50 | % |
| Saturation,23°C,2.00mm | ISO 62 | 1.2 | % | |
| Equilibrium,23°C,2.00mm,50%RH | ISO 62 | 0.30 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | IEC 60093 | 1E+13 | ohms·cm | |
| Relative permittivity | 100Hz | IEC 60250 | 3.50 | |
| 1MHz | IEC 60250 | 3.40 | ||
| Compared to the anti leakage trace index | IEC 60112 | PLC 0 | ||
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | M-Sale | ISO 2039-2 | 92 | |
| R-Sale | ISO 2039-2 | 120 | ||
| Supplementary Information | Test Condition | Test Method | Test Result | Test Unit |
| Emission | VDA275 | <8.00 | mg/kg | |
| EmissionofOrganicCompounds | VDA277 | 16.0 | µgC/g | |
| Odor | VDA270 | 3.00 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.