PC S-2000VUR MITSUBISHI THAILAND
55
Form:Granules | Grade:Weather resistant grade
Properties:
Medium viscosityheat-resistingMedium viscosityFlame retardantDemolding ability
Typical Applications:
Electronic and electrical componentsAutomotive Applications
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Electronic and electrical components | Automotive Applications |
| Properties: | Medium viscosity | heat-resisting | Medium viscosity | Flame retardant | Demolding ability |
Certificates
No Data...
Technical Data Sheet
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | ASTM D256 | 740-1000 | J/m | |
| Bending modulus | ASTM D790 | 2.3 | GPa | |
| bending strength | ASTM D790 | 80.4-90.2 | Mpa | |
| Stretching length | ASTM D638 | 90-140 | % | |
| tensile strength | ASTM D 638 | 58.8-68.6 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Linear coefficient of thermal expansion | 6-7 | 10 | ||
| Combustibility | UL 94 | V-2 | ||
| Hot deformation temperature | 18.6kgf/cm | ASTM D 648 | 130-136 | °C |
| 4.6kgf/cm | ASTM D 648 | 136-142 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | 23℃,24hrs | ASTM D570 | 0.23-0.26 | % |
| density | ASTM D792 | 1.2 | ||
| Shrinkage rate | Across Flow | 0.5-0.8 | % | |
| Flow | 0.5-0.8 | % | ||
| Rockwell hardness | ASTM D785 | 123 | R | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dielectric strength | ASTM D149 | 18-22 | KV/mm | |
| Dielectric loss | 10,Tangent | ASTM D150 | 0.0082 | |
| Dielectric constant | 10 | ASTM D150 | 25.2 | Pf/m |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.