PA12 P110 TL ARKEMA FRANCE
42
Form:Granules
Properties:
LubricityHydrolysis resistanceHigh impact resistancePhotostabilityThermal stabilityUV resistance
Typical Applications:
Pipe fittingsApplications and pipe fittings in the automotive f
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Pipe fittings | Applications and pipe fittings in the automotive f |
| Properties: | Lubricity | Hydrolysis resistance | High impact resistance | Photostability | Thermal stability | UV resistance |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Charpy Notched Impact Strength | 23°C | ISO 179 | 75 | kJ/m² |
| -30°C | ISO 179 | 8.0 | kJ/m² | |
| Impact strength of simply supported beam without notch | 23°C | ISO 179 | NoBreak | |
| -30°C | ISO 179 | NoBreak | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Bending modulus | ISO 178 | 1020 | Mpa | |
| Tensile strain | Break | ISO 527-2 | >150 | % |
| Yield | ISO 527-2 | 13 | % | |
| tensile strength | Break | ISO 527-2 | 45.0 | Mpa |
| Yield | ISO 527-2 | 32.0 | Mpa | |
| Tensile modulus | ISO 527-2 | 1120 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Melting temperature | ISO 11357-3 | 176 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Melt Volume Flow Rate (MVR) | 275°C/5.0kg | ISO 11357 | 0.400 | cm3/10min |
| density | ISO 1183 | 1.00 | g/cm³ | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Shore hardness | ShoreD,15Sec | ISO 868 | 66 | |
| ShoreD | ISO 868 | 73 | ||
| Supplementary Information | Test Condition | Test Method | Test Result | Test Unit |
| ISO Shortcut | ISO 1874 | PA12-HI.EHL.24-010 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.