Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
MeltViscosity | | ISO11443-A | 251 Pa·s |
density | | ISO1183 | 1.17 g/cm³ |
Melt volume flow rate | | ISO1133 | 18.0 cm³/10min |
Water absorption rate | | ISO62 | 0.50 % |
Water absorption rate | | ISO62 | 0.20 % |
flammability | Test Condition | Test Method | Test Result |
---|
FlameRating | | UL94 | HB |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Multi axis Instrumented Impact Energy | | ISO6603-2 | 45.0 J |
Impact strength of cantilever beam gap | | ISO180/A | 38 kJ/m² |
Impact strength of cantilever beam gap | | ISO180/A | 48 kJ/m² |
Multi axis Instrumented Impact Energy | | ISO6603-2 | 45.0 J |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ISO527-2/1 | 2250 MPa |
Tensile stress | | ISO527-2/50 | 56.0 MPa |
Tensile stress | | ISO527-2/50 | 58.0 MPa |
Tensile strain | | ISO527-2/50 | 5.0 % |
Tensile strain | | ISO527-2/50 | >50 % |
Electrical performance | Test Condition | Test Method | Test Result |
---|
CTI | | IEC60112 | 175 V |
Surface Resistivity | | IEC60093 | 1E+16 ohms |
Volume resistivity | | IEC60093 | 1E+16 ohms·cm |
dielectric strength | | IEC60243-1 | 35 kV/mm |
| | IEC60250 | 3.10 |
| | IEC60250 | 3.00 |
Dissipation Factor | | IEC60250 | 0.011 |
Dissipation Factor | | IEC60250 | 2.5E-03 |
Thermal performance | Test Condition | Test Method | Test Result |
---|
| | ISO75-2/B | 126 °C |
| | ISO75-2/A | 110 °C |
vicat | | ISO306/B120 | 132 °C |
| | ISO11359-2 | 7E-05 cm/cm/°C |
| | ISO11359-2 | 7E-05 cm/cm/°C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.