Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTM D792 | 1.48 g/cm³ |
Shrinkage rate | | ASTM D955 | 0.50 % |
Water absorption rate | | ASTM D570 | 0.27 % |
hardness | Test Condition | Test Method | Test Result |
---|
Rockwell hardness | R-Scale | ASTM D785 | 119 |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL 94 | HB |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Wear factor | | ASTM D3702 | 190 10^-8mm³/N·m |
coefficient of friction | Steel - Dynamic | ASTM D1894 | 0.32 |
coefficient of friction | | ASTM D1894 | 0.26 |
tensile strength | Break | ASTM D638 | 186 MPa |
elongation | Break | ASTM D638 | 2.5 % |
Flexural modulus | | ASTM D790 | 11000 MPa |
bending strength | | ASTM D790 | 269 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ASTM D256 | 85 J/m |
Electrical performance | Test Condition | Test Method | Test Result |
---|
dielectric strength | | ASTM D149 | 20 kV/mm |
Volume resistivity | | ASTM D257 | 1E+16 ohms·cm |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ASTM D648 | 301 °C |
Linear coefficient of thermal expansion | | ASTM D696 | 2.2E-05 cm/cm/°C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.