PA6 Akulon® K224-LGM35
46
- Properties:Glass fiber reinforcedLubricityUV resistanceMineral reinforcementFiller: DSM DSM Netherlan
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
Water absorption rate | ISO62 | 1.7 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile modulus | ISO527-2 | 9000 Mpa | |
Tensile stress | ISO527-2 | 120 Mpa | |
Tensile strain | ISO527-2 | 3.0 % | |
Flexural modulus | ISO178 | 7700 Mpa | |
Bending stress | ISO178 | 165 Mpa |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of simply supported beam without notch | ISO179/1eU | 25 kJ/m² | |
ISO179/1eU | 30 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Surface Resistivity | IEC60093 | -- ohms | |
Volume resistivity | IEC60093 | 1E+14 ohms·cm | |
dielectric strength | IEC60243-1 | 35 KV/mm | |
IEC60250 | 3.50 | ||
IEC60250 | 3.30 | ||
Dissipation Factor | IEC60250 | 5E-03 | |
IEC60250 | 0.014 |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
ISO11359-2 | 1E-04 cm/cm/°C | ||
ISO75-2/B | 215 °C | ||
ISO75-2/A | 205 °C | ||
melting temperature | ISO11357-3 | 220 °C | |
ISO11359-2 | 1.8E-05 cm/cm/°C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.