PTFE AD300 Arlon-MED
Product Description
Certificates(0)
Datasheet
Product Description
Certificates
No Data...
Technical Data Sheet
| flammability | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| UL flame retardant rating | UL 94 | V-0 | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | 23°C2 | ASTM D638 | 4870 | MPa |
| 23°C3 | ASTM D638 | 3560 | MPa | |
| Bending modulus | 23°C | ASTM D790 | 3720 | MPa |
| Compressive modulus | ASTM D695 | 2520 | MPa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| thermal conductivity | 100°C | ASTMC177 | 0.24 | W/m/K |
| Linear coefficient of thermal expansion | XAxis:0to100°C | Internal Method | 1.2E-05 | cm/cm/°C |
| YAxis:0to100°C | Internal Method | 1.5E-05 | cm/cm/°C | |
| ZAxis:0to100°C | 9.5E-05 | cm/cm/°C | ||
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ASTM D792A | 2.40 | g/cm³ | |
| Water absorption rate | 23°C,24hr | ASTM D570 | 0.070 | % |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Surface resistivity | Internal Method | 4.5E+07 | ohms | |
| Volume resistivity | Internal Method | 1.2E+15 | ohms·cm | |
| Dielectric constant | 23°C | Internal Method | 3.00 | |
| Dissipation factor | 10.0GHz | Internal Method | 3E-03 | |
| Arc resistance | ASTM D495 | >180 | sec | |
| film | Test Condition | Test Method | Test Result | Test Unit |
| tensile strength | MD:Yield | ASTM D882 | 144 | MPa |
| TD:Yield | ASTM D882 | 119 | MPa | |
| Peel strength | Internal Method | -2.5 | kN/m | |
| Supplementary Information | Test Condition | Test Method | Test Result | Test Unit |
| Breakdown voltage strength | ASTM D149 | >45000 | V |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.