Share
Add to Compare

PC PK2870-21317 SABIC INNOVATIVE US

112

Form:Granules | Grade:Injection grade

Properties:
enhancewear resistant
Typical Applications:
chipFiber grade
Product Description
Certificates(0)
Datasheet

Product Description

Typical Applications:chip | Fiber grade
Properties:enhance | wear resistant

Certificates

No Data...

Technical Data Sheet

optical performanceTest ConditionTest MethodTest ResultTest Unit
Transmittance rate2.54 mmASTM D100388%
impact performanceTest ConditionTest MethodTest ResultTest Unit
Impact strength of cantilever beam gap23℃ASTM D256750J/m
Suspended wall beam without notch impact strength80*10*3,23℃ISO 180/1A75kJ/m²
Suspended wall beam without notch impact strength23℃ASTM D 4812NBJ/m
Suspended wall beam without notch impact strength80*10*3,-30℃ISO 180/1A55kJ/m²
Impact strength of cantilever beam gap/,30℃ASTM D256150 J/m
Charpy Notched Impact StrengthV-notch Edgew,23℃ISO 179/1eA70kJ/m²
Charpy Notched Impact StrengthV-notch Edgew,-30℃ISO 179/1eA50kJ/m²
Suspended wall beam without notch impact strength80*10*3,23℃ISO 180/1UNBkJ/m²
Dart impactASTM D 3029170J
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Bending modulus1.3 mm/minASTM D7902300Mpa
Bending modulus2 mm/miISO 1782300Mpa
bending strength2 mm/,YieldISO 17895Mpa
bending strength1.3 mm/min/,YieldASTM D79095Mpa
Elongation at Break50 mm/mISO 52770%
Elongation at BreakType I, 5ASTM D63870%
elongation50 mm/m,YieldISO 527%
elongationType I, 5,YieldASTM D638%
tensile strengthType I, 50,BreakASTM D63865 Mpa
tensile strength50 mm/m,BreakISO 52770Mpa
tensile strength50 mm/m,YieldISO 52765Mpa
tensile strengthType I, 5,YieldASTM D63862Mpa
thermal propertiesTest ConditionTest MethodTest ResultTest Unit
Vicat softening temperatureRate B/5ASTM D1525150°C
Vicat softening temperatureRate B/5ISO 306150°C
Vicat softening temperatureRate B/5ISO 306149°C
specific heatASTM C 3511.25J/g-°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
Water absorption rate23°C / 50ISO 620.15
Water absorption rate23°C/satISO 620.35
Water absorption rateequilibriuASTM D5700.35
Water absorption rateequilibriuASTM D5700.58
Shrinkage rateflow, 3.Internal0.5-0.7 
melt mass-flow rate/ASTM D12382.5 g/10min
Melt Volume Flow Rate (MVR)300°C/2.16 kgISO 11334cm³/10 min
Melt Volume Flow Rate (MVR)300°C/1.2 kgISO 1133cm³/10 min
hardnessTest ConditionTest MethodTest ResultTest Unit
Hardness (Rockwell R)ISO 2039-2120R
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.

Sourcing & Prices

Selling & Verification

Explore Materials

Price Index

+86 0755 27873515

Room 906, Global Digital Building, No. 9 Gaoxin Middle 3rd Road, Maling Community, Yuehai Subdistrict, Nanshan District, Shenzhen, Guangdong Province, China