PP AP3N EXXONMOBIL SINGAPORE
52
Form:Granules | Grade:Injection grade
Properties:
High rigidityHigh glossMiddle flowFast forming cycle
Typical Applications:
Electrical appliancesHome appliance componentsConsumer goods sectorConsumer product application field
Product Description
Certificates(2)
Datasheet
Product Description
| Typical Applications: | Electrical appliances | Home appliance components | Consumer goods sector | Consumer product application field |
| Properties: | High rigidity | High gloss | Middle flow | Fast forming cycle |
Certificates

TDS
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Charpy Notched Impact Strength | -20°C | ISO 179/1eA | 4.0 | kJ/m² |
| 0°C | ISO 179/1eA | 4.5 | kJ/m² | |
| 23°C | ISO 179/1eA | 8.6 | kJ/m² | |
| Impact strength of cantilever beam gap | 23°C | ASTM D256A | 96 | J/m |
| -40°C | ISO 180/1A | 3.8 | kJ/m² | |
| -18°C | ISO 180/1A | 4.5 | kJ/m² | |
| 23°C | ISO 180/1A | 8.3 | kJ/m² | |
| Dart impact | -29°C,3.18mm | ASTM D5420 | 18.0 | J |
| Charpy Notched Impact Strength | -30°C | ISO 179/1eA | 3.6 | kJ/m² |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | ISO 527-2/1 | 1690 | Mpa | |
| tensile strength | Yield3 | ASTM D638 | 28.8 | Mpa |
| Yield | ISO 527-2/50 | 28.2 | Mpa | |
| elongation | Yield3 | ASTM D638 | 5.0 | % |
| Yield | ISO 527-2/50 | 5.0 | % | |
| Bending modulus | 1%Secant4 | ASTM D790A | 1480 | Mpa |
| 1%Secant5 | ASTM D790B | 1710 | Mpa | |
| --6 | ISO 178 | 1510 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45MPa,Unannealed | ASTM D648 | 114 | °C |
| 0.45MPa,Unannealed | ISO 75-2/Bf | 100 | °C | |
| 0.45MPa,Annealed | ASTM D648 | 123 | °C | |
| 1.8MPa,Unannealed | ISO 75-2/A | 54.0 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| melt mass-flow rate | 230°C/2.16kg | ASTM D1238 | 10 | g/10min |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | ASTM D785 | 98 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.