PC ML-3110ZLP TEIJIN JAPAN
90
Form:Granules | Grade:High liquidity level
Properties:
transparentUV resistancehigh strengthWeather resistanceFlame retardantoptical performance
Typical Applications:
Electrical fieldElectronic fieldHousehold appliancesHousehold appliancesCasters
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Electrical field | Electronic field | Household appliances | Household appliances | Casters |
| Properties: | transparent | UV resistance | high strength | Weather resistance | Flame retardant | optical performance |
Certificates
No Data...
Technical Data Sheet
| optical performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Pigment dispersion | 2.0mmt | In-house method | 60 | % |
| Transmittance rate | 1.5mmt | JIS K7136 | 59 | % |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Impact strength of cantilever beam gap | Notched | ISO 179 | 10 | kJ/m² |
| bending strength | 2mm/min | ISO 178 | 99 | Mpa |
| Bending modulus | 2mm/min | ISO 178 | 2400 | Mpa |
| Elongation at Break | 50mm/min | ISO 527-1 | 105 | % |
| tensile strength | 50mm/min,Break | ISO 527-1 | 68 | Mpa |
| 50mm/min,Yield | ISO 527-1 | 61 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | TD | ISO 11359-2 | 0.7 | X10-4/℃ |
| UL flame retardant rating | 1.0mm | UL 94 | V-2 | |
| Hot deformation temperature | 线膨胀系数,MD | ISO 11359-2 | 0.7 | X10-4/℃ |
| 1.80MPa | ISO 75-1 | 129 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | TD | In-house method | 0.5-0.7 | % |
| MD | In-house method | 0.5-0.7 | % | |
| Dissolving fingers | 300℃ | ISO 1133 | 18 | cm310min |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.