PA6 POLYBEST 6 PD GF50 black POLYMA Kunststoff GmbH & Co. KG
0
- Properties:Filler glass fiber reinforced material 50% filler by weight
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Suspended wall beam without notch impact strength | kJ/m² | >90 -- |
| flammability | Test Condition | Test Method | Test Result |
|---|---|---|---|
| UL flame retardant rating | 1.6mm | HB -- |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Bending modulus | MPa | 13500 8500 | |
| elongation | Break | % | 2.0 3.0 |
| tensile strength | Break | MPa | 230 180 |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Hot deformation temperature | 1.8MPa,Unannealed | °C | 215 -- |
| 0.45MPa,Unannealed | °C | 220 -- | |
| Melting temperature | °C | 222 -- |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Shrinkage rate | MD | % | 0.15 -- |
| density | g/cm³ | 1.57 -- | |
| Water absorption rate | 23°C,24hr | % | 0.80 -- |
| Electrical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Compared to the anti leakage trace index | V | PLC 1 | |
| Volume resistivity | ohms·cm | 1E+15 1E+11 | |
| Surface resistivity | ohms | 1E+13 1E+11 |
| hardness | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Rockwell hardness | R-Scale | 120 110 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.