Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTMD792 | 1.32 g/cm³ |
Water absorption rate | | ISO62 | 5.5 % |
Water absorption rate | | ISO62 | 0.95 % |
flammability | Test Condition | Test Method | Test Result |
---|
Burning wire flammability index | | IEC60695-2-12 | 960 °C |
Burning wire flammability index | | IEC60695-2-12 | 960 °C |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
tensile strength | Break | ASTMD638 | 70.0 MPa |
elongation | Break | ASTMD638 | 3.3 % |
bending strength | | ASTMD790 | 140 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ASTMD256A | 50 J/m |
Electrical performance | Test Condition | Test Method | Test Result |
---|
dielectric strength | | ASTMD149 | 25 kV/mm |
CTI | | IEC60112 | 600 V |
Thermal performance | Test Condition | Test Method | Test Result |
---|
| | ASTMD648 | 165 °C |
| | ASTMD648 | 205 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.