Technical Data Sheet
thermosetting | Test Condition | Test Method | Test Result |
---|---|---|---|
STORAGE STABILITY | 2900 min | ||
shelf-life | 52 wk | ||
52 wk | |||
26 wk | |||
7000 cP | |||
Post curing time | 6.0 hr | ||
0.50 hr |
Supplementary Information | Test Condition | Test Method | Test Result |
---|---|---|---|
Ionic Chloride | <300 ppm | ||
IonicPotassium | <30 ppm | ||
IonicSodium | <10 ppm | ||
LapShear-Aluminum | >1700 | ||
MixingRatio-PartA:PartB | 1:1 | ||
ShearStrength-Gold | 108 N | ||
WaterExtractConductivity | 80.0 µS/cm |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Volume resistivity | 2E+13 ohms·cm | ||
dielectric constant | 4.30 | ||
Dissipation Factor | 0.025 |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Glass Transition Temperature | 85.0 °C | ||
thermal conductivity | 0.70 W/m/K |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.
Contact Us
Get App