PA66 CM3004-V0 TORAY SYN THAILAND
37
Form:Granules | Grade:Flame retardant grade
Properties:
Flame retardantHalogen-freeNylon 66UnreinforcedEnvironmental protection Non-Halogen Nylon 66UnreinforcedEnvironmental protection Non-Halogen
Typical Applications:
OA deviceElectrical appliancesElectrical componentsShellMainly used for electrical accessoriesConnectorElectric motor casing etc
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | OA device | Electrical appliances | Electrical components | Shell | Mainly used for electrical accessories | Connector | Electric motor casing | etc |
| Properties: | Flame retardant | Halogen-free | Nylon 66 | Unreinforced | Environmental protection | Non-Halogen | Nylon 66 | Unreinforced | Environmental protection | Non-Halogen |
Certificates
No Data...
Technical Data Sheet
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Rockwell hardness | R标尺 | ISO 2239/2 | 118 | |
| tensile strength | ISO 527 | 85 | Mpa | |
| elongation | Break | ISO 527 | 17 | % |
| bending strength | ISO 178 | 122 | Mpa | |
| Bending modulus | ISO 178 | 3400 | Mpa | |
| Charpy Notched Impact Strength | 23℃ | ISO 179 | 15 | kJ/m² |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.80MPa | ISO 75 | 115 | °C |
| Melting temperature | ISO 3461 | 235 | °C | |
| UL flame retardant rating | UL -94 | V-0 | ||
| Extreme Oxygen Index | ISO 4589 | 24.5 | ||
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ISO 1183 | 1.18 | g/cm³ | |
| Shrinkage rate | ISO 294-4 | 0.7-1.0 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Surface resistivity | IEC 60093 | 1013 | ||
| Volume resistivity | IEC 60093 | 1014 | ||
| Dielectric strength | IEC 60243 | 22 | KV/mm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.