PA6 FR-301 SHANGHAI CELLULOID
85
Form:Granules | Grade:Flame retardant grade
Properties:
high strengthHigh impact resistanceGlass fiber reinforcedBrominationFlame retardantBromine containing flame 20% glass fiber reinforceLow deformationHigh strength
Product Description
Certificates(0)
Datasheet
Product Description
| Properties: | high strength | High impact resistance | Glass fiber reinforced | Bromination | Flame retardant | Bromine containing flame | 20% glass fiber reinforce | Low deformation | High strength |
Certificates
No Data...
Technical Data Sheet
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | GB1043 | 12 | KJ/m | |
| Bending modulus | 6135 | Mpa | ||
| bending strength | GB1042 | 163 | Mpa | |
| elongation | 2 | % | ||
| tensile strength | GB1040 | 116 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.8Mpa | GB1634 | 204 | °C |
| UL flame retardant rating | UL 94 | V-0 | ||
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Melting temperature | 215 | °C | ||
| density | GB1033 | 1.37 | ||
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | GB1410 | 4.2×10 | Ω.m | |
| Dielectric loss | 1MHz | GB1409 | 0.01 | |
| Dielectric constant | 60MHz | GB1409 | 1.8 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.