PA6 C 216 V30 SOLVAY SHANGHAI
249
Form:Granules | Grade:Injection grade
Properties:
High mobility 30% glass fiber reinforcGood mechanical and therm
Typical Applications:
Household appliancesfurnituresporting goodsWidely used in various industrial fields
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Household appliances | furniture | sporting goods | Widely used in various industrial fields |
| Properties: | High mobility | 30% glass fiber reinforc | Good mechanical and therm |
Certificates
No Data...
Technical Data Sheet
| Basic Performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Water absorption rate | 23℃,24hr | ISO 62 | 0.9 | % |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | RH0/RH50 | ISO 527-2 | 9600/6200 | Mpa |
| Elongation at Break | ISO 527-2 | 190/110 | Mpa | |
| Charpy Notched Impact Strength | RH0/RH50 | ISO 179/1eA | 15/31.5 | kJ/m² |
| Impact strength of simply supported beam without notch | ISO 179/1eU | 100/108 | kJ/m² | |
| Elongation at Break | RH0/RH50 | ISO 527-2 | 3.8/4.5 | % |
| Impact strength of cantilever beam gap | RH0/RH50 | ISO 180/1A(93) | 14/24 | kJ/m² |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Linear coefficient of thermal expansion | 23-85℃ | ASTM E-831 | 3.2 | 10-5·K-1 |
| Melting temperature | ISO 3146-C | 222 | °C | |
| Hot deformation temperature | 1.80MPa | ISO 75-2 | 205 | °C |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dielectric loss | RH0/RH50,1MHz | IEC 250 | 0.02/0.009 | |
| Dielectric constant | RH0/RH50,1MHz | IEC 250 | 3.8/4.5 | |
| Volume resistivity | IEC 93 | 1015/1011 | Ω.cm | |
| Dielectric strength | RH0/RH50 | ISO 180/1A(93) | -/22 | kJ/m² |
| Anti arc track KC | RH0/RH50 | IEC 112 | 550 | V |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.