PPO(PPE)+PS Jamplast JPPPO30GF Jamplast, Inc.
Properties:
Filler glass fiber reinforced material 20% filler by weight
Typical Applications:
Pump components casing valves valve parts
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Pump components | casing | valves | valve parts |
| Properties: | Filler | glass fiber reinforced material | 20% | filler by weight |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | -40°C | ASTM D256 | 96 | J/m |
| 23°C | ASTM D256 | 120 | J/m | |
| Suspended wall beam without notch impact strength | 23°C | ASTM D256 | 650 | J/m |
| Dart impact | 23°C,TotalEnergy | ASTM D3763 | 22.6 | J |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 1.5mm | UL 94 | HB | |
| Extreme Oxygen Index | ASTM D2863 | 26 | % | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | ASTM D638 | 6200 | MPa | |
| tensile strength | Break | ASTM D638 | 90.3 | MPa |
| elongation | Break | ASTM D638 | 2.6 | % |
| Bending modulus | 50.0mmSpan | ASTM D790 | 5800 | MPa |
| bending strength | Yield,50.0mmSpan | ASTM D790 | 160 | MPa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45MPa,Unannealed,3.20mm | ASTM D648 | 141 | °C |
| RTI Imp | UL 746 | 90.0 | °C | |
| RTI | UL 746 | 90.0 | °C | |
| Linear coefficient of thermal expansion | MD:-40to40°C | ASTME831 | 2.9E-05 | cm/cm/°C |
| TD:-40to40°C | ASTME831 | 8.3E-05 | cm/cm/°C | |
| RTI Elec | UL 746 | 90.0 | °C | |
| Hot deformation temperature | 0.45MPa,Unannealed,6.40mm | ASTM D648 | 143 | °C |
| 1.8MPa,Unannealed,3.20mm | ASTM D648 | 135 | °C | |
| 1.8MPa,Unannealed,6.40mm | ASTM D648 | 138 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ASTM D792 | 1.20 | g/cm³ | |
| melt mass-flow rate | 300°C/5.0kg | ASTM D1238 | 9.0 | g/10min |
| Shrinkage rate | MD:3.20mm | ASTM D955 | 0.20to0.50 | % |
| Water absorption rate | 24hr | ASTM D570 | 0.060 | % |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dielectric strength | 3.20mm,inOil | ASTM D149 | 17 | kV/mm |
| Dielectric constant | 50Hz | ASTM D150 | 2.86 | |
| High voltage arc tracing rate | HVTR | UL 746 | PLC 4 | |
| Hot wire ignition | HWI | UL 746 | PLC 4 | |
| Dielectric constant | 60Hz | ASTM D150 | 2.86 | |
| Dissipation factor | 50Hz | ASTM D150 | 8E-04 | |
| 60Hz | ASTM D150 | 8E-04 | ||
| Arc resistance | ASTM D495 | PLC7 | ||
| High arc combustion index | HAI | UL 746 | PLC 4 | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | L-Sale | ASTM D785 | 106 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.