PA6 Alloy Orgalloy® R 60ES ARKEMA FRANCE
Product Description
Certificates(0)
Datasheet
Product Description
Certificates
No Data...
Technical Data Sheet
| flammability | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Burning Behav.atthicknessh | 3.20mm | ISO 12102 | HB | |
| Burning Behav. | 1.60mm | ISO 12102 | HB | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile creep modulus | 1000hr | ISO 899-12 | -- | MPa |
| 1hr | ISO 899-12 | -- | MPa | |
| Nominal fracture strain | ISO 527-22 | -- | % | |
| Tensile strain | Yield | ISO 527-22 | -- | % |
| tensile strength | Yield | ISO 527-22 | -- | MPa |
| Tensile modulus | ISO 527-22 | -- | MPa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Vicat softening temperature | 50N | ISO 3062 | 129 | °C |
| Hot deformation temperature | 1.8MPa | ISO 75-22 | 75.0 | °C |
| 0.45MPa | ISO 75-22 | 130 | °C | |
| Linear coefficient of thermal expansion | TD | ISO 11359-22 | 1.3E-04 | cm/cm/°C |
| MD | ISO 11359-22 | 9.3E-05 | cm/cm/°C | |
| Melting temperature | ISO 11357-32 | 220 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | Equilibrium | ISO 622 | 1.3 | % |
| Saturation | ISO 622 | 3.3 | % | |
| Melt Volume Flow Rate (MVR) | 235°C/2.16kg | ISO 11332 | 2.00 | cm³/10min |
| density | ISO 11832 | 1030 | kg/m³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dissipation factor | 1MHz | IEC 602502 | -- | |
| 100Hz | IEC 602502 | -- | ||
| Relative permittivity | 1MHz | IEC 602502 | -- | |
| 100Hz | IEC 602502 | -- | ||
| Dielectric strength | IEC 60243-12 | 38 | kV/mm | |
| Volume resistivity | IEC 600932 | -- | ohms·m | |
| Surface resistivity | IEC 600932 | -- | ohms |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.