Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
Shrinkage rate | ISO 2577 | 0.10to0.20 % | |
ISO 2577 | 0.70to0.90 % | ||
ISO 2577 | 0.10to0.20 % | ||
Water absorption rate | ISO 62 | 0.50 % | |
ISO 62 | 0.20 % | ||
density | ISO 1183 | 1.20 g/cm³ | |
Apparent density | ISO 60 | 0.65 g/cm³ | |
Melt volume flow rate | ISO 1133 | 44.0 cm³/10min | |
Shrinkage rate | ISO 2577 | 0.70to0.90 % |
hardness | Test Condition | Test Method | Test Result |
---|---|---|---|
ball-indentation hardness | ISO 2039-1 | 107 MPa |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
UL flame retardant rating | UL 94 | HB | |
Burning wire flammability index | IEC 60695-2-12 | 750 °C | |
Limiting Oxygen Index | ISO 4589-2 | 21 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Bending Strain | ISO 178 | 6.0 % | |
Flexural modulus | ISO 178 | 2150 MPa | |
bending strength | ISO 178 | 80.0 MPa | |
ISO 178 | 70.0 MPa | ||
Tensile modulus | ISO 527-2/1 | 2200 MPa | |
tensile strength | ISO 527-2/50 | 60.0 MPa | |
ISO 527-2/50 | 50.0 MPa | ||
Tensile strain | ISO 527-2/50 | 5.0 % | |
Nominal tensile fracture strain | ISO 527-2/50 | >100 % |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Charpy Notched Impact Strength | ISO 179/1eA | 25 kJ/m² | |
ISO 179/1eA | 55 kJ/m² | ||
Impact strength of simply supported beam without notch | ISO 179/1eU | NoBreak | |
ISO 179/1eU | NoBreak | ||
Impact strength of cantilever beam gap | ISO 180/A | 20 kJ/m² | |
ISO 180/A | 25 kJ/m² | ||
ISO 180/A | 35 kJ/m² | ||
ISO 180/A | 40 kJ/m² | ||
Suspended wall beam without notch impact strength | ISO 180 | NoBreak | |
ISO 180 | NoBreak | ||
Multi axis Instrumented Impact Energy | ISO 6603-2 | 55.0 J | |
ISO 6603-2 | 45.0 J | ||
Multi axis Instrumented Peak Impact Force | ISO 6603-2 | 4800 N | |
ISO 6603-2 | 3600 N |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Surface Resistivity | IEC 60093 | >1.0E+17 ohms | |
Volume resistivity | IEC 60093 | >1.0E+17 ohms·cm | |
dielectric strength | IEC 60243-1 | 30 kV/mm | |
relative permittivity | IEC 60250 | 3.20 | |
IEC 60250 | 3.00 | ||
Dissipation Factor | IEC 60250 | 6E-04 | |
IEC 60250 | 4.5E-03 | ||
Compared to the Leakage Tracking Index (CTI) | IEC 60112 | PLC 0 | |
IEC 60112 | PLC 4 |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Heat distortion temperature | ISO 75-2/B | 105 °C | |
ISO 75-2/A | 82.0 °C | ||
vicat | ISO 306/B120 | 122 °C | |
Linear coefficient of thermal expansion | ISO 11359-2 | 9E-05 cm/cm/°C | |
ISO 11359-2 | 9E-05 cm/cm/°C | ||
thermal conductivity | ISO 8302 | 0.20 W/m/K |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.