Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTM D792 | 1.53 |
density | | ISO1183 | 1.53 g/cm³ |
melt mass-flow rate | | ISO1133 | 10 g/10min |
MediumDensity | | | 1.36 g/cm³ |
Ejection Temperature | | | 170 °C |
Melt volume flow rate | | ISO1133 | 7.00 cm3/10min |
Shrinkage rate | | ISO294-4 | 1.1 % |
Shrinkage rate | | ISO294-4 | 0.30 % |
Water absorption rate | | ISO62 | 0.35 % |
Water absorption rate | | ISO62 | 0.15 % |
viscosity number | | ISO307 | 100 cm³/g |
SpecificHeatCapacity of Melt | | | 1730 J/kg/°C |
ThermalConductivityofMelt | | | 0.28 W/m/K |
flammability | Test Condition | Test Method | Test Result |
---|
Burning rate 3 | | ISO3795 | 41 mm/min |
UL flame retardant rating | | UL94 | HB |
UL flame retardant rating | | UL94 | HB |
UL flame retardant rating | | IEC60695-11-10,-20 | HB |
UL flame retardant rating | | IEC60695-11-10,-20 | HB |
Limiting Oxygen Index | | ISO4589-2 | 19 % |
FMVSS flammability | | FMVSS302 | B |
Fogging-F-value | | ISO6452 | 99 % |
Supplementary Information | Test Condition | Test Method | Test Result |
---|
Emissions of Organic Compounds | | VDA277 | 140 µgC/g |
Odor | | VDA270 | 3.00 |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Non notched impact strength | | ASTM D256 | 1120 J/m |
Non notched impact strength | | ASTM D256 | 998 J/m |
compressive strength | | ASTM D695 | 202 MPa |
tensile strength | | ASTM D638 | 140 MPa |
Tensile modulus | | ASTM D638 | 10000 MPa |
Flexural modulus | | ASTM D790 | 8970 MPa |
Across Flow | | ASTM D638 | 2.6 % |
Low temperature notch impact strength | | ASTM D256 | 101 J/m |
Notch impact strength | | ASTM D256 | 101 J/m |
Notch impact strength | | ASTM D256 | 112 J/m |
Tensile modulus | | ISO527-2 | 10000 Mpa |
Tensile stress | | ISO527-2 | 140 Mpa |
Tensile strain | | ISO527-2 | 2.7 % |
TensileCreepModule | | ISO899-1 | 9000 Mpa |
Tensile creep modulus | | ISO899-1 | 6600 Mpa |
Flexural modulus | | ISO178 | 9000 Mpa |
Bending stress | | ISO178 | 200 Mpa |
Other performance | Test Condition | Test Method | Test Result |
---|
Limiting Oxygen Index | | ASTM D2863 | 19 % |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Charpy Notched Impact Strength | | ISO179/1eA | 10 kJ/m² |
Charpy Notched Impact Strength | | ISO179/1eA | 11 kJ/m² |
Charpy Notched Impact Strength | | ISO179/1eA | 10 kJ/m² |
Impact strength of simply supported beam without notch | | ISO179/1eU | 75 kJ/m² |
Impact strength of simply supported beam without notch | | ISO179/1eU | 75 kJ/m² |
Impact strength of simply supported beam without notch | | ISO179/1eU | 70 kJ/m² |
Impact strength of cantilever beam gap | | ISO180/1A | 10 kJ/m² |
Impact strength of cantilever beam gap | | ISO180/1A | 10 kJ/m² |
Impact strength of cantilever beam gap | | ISO180/1A | 11 kJ/m² |
| | ISO180/1U | 55 kJ/m² |
| | ISO180/1U | 55 kJ/m² |
| | ISO180/1U | 60 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Surface Resistivity | | IEC60093 | >1.0E+15 ohms |
Volume resistivity | | IEC60093 | >1.0E+15 ohms·cm |
dielectric strength | | IEC60243-1 | 38 KV/mm |
| | IEC60250 | 3.90 |
| | IEC60250 | 3.80 |
Dissipation Factor | | IEC60250 | 7.5E-04 |
Dissipation Factor | | IEC60250 | 0.018 |
CTI | | IEC60112 | 400 V |
Thermal performance | Test Condition | Test Method | Test Result |
---|
| | ASTM D648 | 220 ℃ |
| | ASTM D648 | 205 ℃ |
| | ASTM E831 | 0.000030 cm/cm/℃ |
| | ASTM E831 | 0.000090 cm/cm/℃ |
UL flame retardant rating | | | UL 94 HB |
UL flame retardant rating | | | UL 94 HB |
UL flame retardant rating | | | UL 94 HB |
| | ISO11359-2 | 9E-05 cm/cm/°C |
| | ISO75-2/B | 220 °C |
| | ISO75-2/A | 205 °C |
vicat | | ISO306/B50 | 215 °C |
melting temperature | | ISO11357-3 | 224 °C |
| | ISO11359-2 | 3E-05 cm/cm/°C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.