LCP KEBAFLOW® LCP HF140 BARLOG plastics GmbH
0
- Properties:Filler glass fiber reinforced material 40% filler by weight
Technical Data Sheet
| flammability | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Flammability level | 0.8mm | IEC 60695-11-10,-20 | V-0 |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Tensile modulus | ISO 527-2 | 15000 MPa | |
| tensile strength | Break | ISO 527-2 | 140 MPa |
| Tensile strain | Break | ISO 527-2 | 1.5 % |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 308 °C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| density | ISO 1183 | 1.68 g/cm³ | |
| Shrinkage rate | TD | ISO 294-4 | 0.50 % |
| MD | ISO 294-4 | 0.18 % | |
| Water absorption rate | Saturation,23°C | Internal Method | 0.020 % |
| Electrical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Surface resistivity | IEC 60093 | 1E+15 ohms | |
| Volume resistivity | IEC 60093 | 1E+15 ohms·cm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.