Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
Melt volume flow rate | ISO1133 | 40.0 cm³/10min | |
Shrinkage rate | 内部方法 | 0.60to0.80 % | |
Water absorption rate | ISO62 | 0.16 % | |
ISO62 | 0.35 % | ||
density | ASTMD792 | 1.20 g/cm³ | |
ISO1183 | 1.20 g/cm³ | ||
melt mass-flow rate | ASTMD1238 | 8.0 g/10min |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Flexural modulus | ISO178 | 2300 MPa | |
bending strength | ISO178 | 100 MPa | |
Tensile modulus | ASTMD638 | 2100 MPa | |
ISO527-2/1 | 2150 MPa | ||
tensile strength | Yield | ASTMD638 | 64.0 MPa |
bending strength | ASTMD790 | 95.0 MPa | |
Tensile strain | Break | ISO527-2/50 | 85 % |
Flexural modulus | ASTMD790 | 2200 MPa | |
Tensile stress | Yield | ISO527-2/50 | 65.0 MPa |
tensile strength | Break | ASTMD638 | 69.0 MPa |
Tensile stress | Break | ISO527-2/50 | 60.0 MPa |
elongation | Yield | ASTMD638 | 7.0 % |
Tensile strain | Yield | ISO527-2/50 | 6.0 % |
elongation | Break | ASTMD638 | >50 % |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Charpy Notched Impact Strength | ISO179/1eA | 12 kJ/m² | |
ISO179/1eA | 50 kJ/m² | ||
ISO180/1U | NoBreak | ||
Dart impact equipped with measuring instruments | ASTMD3763 | 120 J | |
Impact strength of simply supported beam without notch | ISO179/1eU | NoBreak | |
ISO179/1eU | NoBreak | ||
Impact strength of cantilever beam gap | ASTMD256 | 130 J/m | |
ASTMD256 | 600 J/m | ||
ISO180/1A | 11 kJ/m² | ||
ISO180/1A | 45 kJ/m² | ||
ISO180/1U | NoBreak |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
ASTMD648 | 139 °C | ||
ISO75-2/Af | 134 °C | ||
vicat | ASTMD152510 | 162 °C | |
ISO306/B50 | 151 °C | ||
ISO306/B120 | 153 °C | ||
BallPressure Test | IEC60695-10-2 | Pass | |
ASTME831 | 8E-05 cm/cm/°C | ||
ISO11359-2 | 8E-05 cm/cm/°C | ||
ASTME831 | 8E-05 cm/cm/°C | ||
ISO11359-2 | 8E-05 cm/cm/°C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.