Share
Add to Compare

NBR NANCAR® 1052M30 Nantex Industry Co., Ltd.

Product Description
Certificates(0)
Datasheet

Product Description

Certificates

No Data...

Technical Data Sheet

elastomerTest ConditionTest MethodTest ResultTest Unit
tensile strength300%Strain7ASTM D4129.51MPa
tensile strengthYield2ASTM D41222.2MPa
tensile strengthYield3ASTM D41223.8MPa
tensile strengthYield4ASTM D41225.2MPa
elongationBreak5ASTM D412740%
tensile strength300%Strain5ASTM D4127.65MPa
tensile strength300%Strain6ASTM D4128.83MPa
elongationBreak6ASTM D412680%
elongationBreak7ASTM D412660%
tear strengthASTM D62457.9kN/m
Permanent compression deformation100°C,70hrASTM D39556%
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Heat lossASTM D56880.40%
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
density0.980g/cm³
Mooney viscosityML1+4,100°CASTM D164633MU
Soluble inMEK100%
bound acrylonitrile contentInternal Method33.0%
stabilizerNon-staining
hardnessTest ConditionTest MethodTest ResultTest Unit
Shore hardnessShoreA2ASTM D224069
Shore hardnessShoreA3ASTM D224071
Shore hardnessShoreA4ASTM D224072
agingTest ConditionTest MethodTest ResultTest Unit
Change rate of tensile strength in air100°C,70hrASTM D8658.0%
Change rate of ultimate elongation in air100°C,70hrASTM D865-26%
Change rate of hardness (Shore) in the airShoreA,100°C,70hrASTM D8657.0
Change rate of tensile strength in air100°C,70hr,在ASTM#1油中ASTM D4715.0%
Change rate of tensile strength in air100°C,70hr,在ASTM#3油中ASTM D471-11%
Change rate of ultimate elongation in air100°C,70hr,在ASTM#1油中ASTM D471-25%
Change rate of ultimate elongation in air100°C,70hr,在ASTM#3油中ASTM D471-16%
Change rate of hardness (Shore) in the air支撐A,100°C,70hr,在ASTM#1油中ASTM D4711.0
Change rate of hardness (Shore) in the air支撐A,100°C,70hr,在ASTM#3油中ASTM D471-14
Volume change100°C,70hr,ASTM标准油(1号)ASTM D4710.20%
Volume change100°C,70hr,ASTM标准油(3号)ASTM D47121%
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.