Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ISO1183 | 1.38 g/cm³ |
Shrinkage rate | | ISO294-4 | 0.60 % |
Shrinkage rate | | ISO294-4 | 0.20 % |
Water absorption rate | | ISO62 | 1.9 % |
Water absorption rate | | ISO62 | 4.7 % |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL94 | V-0 |
UL flame retardant rating | | UL94 | V-0 |
UL flame retardant rating | | UL94 | V-0 |
Burning wire flammability index | | IEC60695-2-12 | 960 °C |
Hot filament ignition temperature | | IEC60695-2-13 | 750 °C |
Hot filament ignition temperature | | IEC60695-2-13 | 800 °C |
Limiting Oxygen Index | | ISO4589-2 | 29 % |
UL flame retardant rating | | UL94 | V-2 |
Burning wire flammability index | | IEC60695-2-12 | 900 °C |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Charpy Notched Impact Strength | | ISO179/1eA | 4.0 kJ/m² |
Charpy Notched Impact Strength | | ISO179/1eA | 4.5 kJ/m² |
Impact strength of simply supported beam without notch | | ISO179/1eU | 29 kJ/m² |
Impact strength of simply supported beam without notch | | ISO179/1eU | 33 kJ/m² |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ISO527-2 | 8800 MPa |
Tensile stress | | ISO527-2 | 100 MPa |
Tensile strain | | ISO527-2 | 2.5 % |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Surface Resistivity | | IEC60093 | 1E+13 ohms |
Volume resistivity | | IEC60093 | 1E+15 ohms·cm |
dielectric strength | | IEC60243-1 | 18 kV/mm |
CTI | | IEC60112 | 600 V |
needle flame test | | IEC60695-11-5 | 通过 |
needle flame test | | IEC60695-11-5 | 通过 |
Thermal performance | Test Condition | Test Method | Test Result |
---|
| | ISO75-2/B | >250 °C |
| | ISO75-2/A | >250 °C |
Continuous use temperature | | IEC60216 | 130 °C |
BallPressure Test | | IEC60695-10-2 | 通过 |
BallPressure Test | | IEC60695-10-2 | 通过 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.