Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
density | ASTM D792 | 1.24 g/cm³ | |
Shrinkage rate | 0.090 % | ||
Water absorption rate | ASTM D570 | <0.80 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Flexural modulus | ASTM D790 | 7800 MPa | |
bending strength | ASTM D790 | 170 MPa | |
Compression Modulus | ASTM D695 | 5060 MPa | |
compressive strength | ASTM D695 | 98.0 MPa | |
Tensile modulus | ASTM D638 | 8800 MPa | |
tensile strength | ASTM D638 | 77.0 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of cantilever beam gap | ASTM D256 | 84.0 kJ/m² | |
Suspended wall beam without notch impact strength | ASTM D256 | 79.0 kJ/m² |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.