Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
ASTM D-955 | 0.4-0.8 % | ||
density | ASTM D-792 | 1.18 | |
fire retardancy | UL 94 | HB CLASS | |
refractive index | ASTM D-542 | 1.49 | |
transmittance | ASTM D-1003 | 93 % |
Basic performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Water absorption rate | ASTM D-570 | 0.3 % | |
melt mass-flow rate | ASTM D-1238 | 2 g/min |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
bending strength | ASTM D-790 | 1460(143) Kgf/cm | |
Flexural modulus | ASTM D-790 | 34000 Kgf/cm | |
tensile strength | ASTM D-638 | 767(75) Kgf/cm | |
Rockwell hardness | ASTM D-758(M级) | 99 | |
Impact Strength | ASTM D-256 | 14(1.6) kg-cm(J) | |
ASTM D-256 | 1.5(14.7) kgf-cm/cm(J/m) |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
vicat | ASTM D-1525 | 235 F | |
Temperature range for use | 85-105 | ||
vicat | ASTM D-1525 | 113 °C | |
ASTM D-648 | 103 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.