PA66 VITAMIDE® AO16BK8507

0
  • Properties:
    Filler
    glass fiber reinforced material
    30%
    filler by weight

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
densityASTMD792,ISO11831.37 g/cm³
Water absorption rateASTMD570,ISO620.80 %
flammabilityTest ConditionTest MethodTest Result
Limiting Oxygen IndexASTMD2863,ISO4589-223 %
UL flame retardant ratingUL94HB
Impact resistanceTest ConditionTest MethodTest Result
Charpy Notched Impact StrengthISO17911 kJ/m²
CharpyUnnotchedASTMD25635.0 kJ/m²
Charpy Notched Impact StrengthASTMD25611.0 kJ/m²
Impact strength of simply supported beam without notchISO17935 kJ/m²
Mechanical propertiesTest ConditionTest MethodTest Result
tensile strengthBreakASTMD638,ISO527-2180 MPa
elongationBreakASTMD638,ISO527-23.0 %
Flexural modulusASTMD790,ISO1788000 MPa
bending strengthASTMD790,ISO178240 MPa
Electrical performanceTest ConditionTest MethodTest Result
Volume resistivityASTMD257,IEC600931E+15 ohms·cm
Thermal performanceTest ConditionTest MethodTest Result
ASTMD2117,ISO1218260 °C
ASTMD6962.5E-05 cm/cm/°C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.