PA66 MN201-G0ST BRICI BEIJING
72
Form:Granules
Properties:
Low temperature toughnessLow temperature impact reProcessability
Typical Applications:
Protective gearSupporting suppliesAutomotive interior partsUsed for automotive interior partsLow temperature resistant products such as sports
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Protective gear | Supporting supplies | Automotive interior parts | Used for automotive interior parts | Low temperature resistant products such as sports |
| Properties: | Low temperature toughness | Low temperature impact re | Processability |
Certificates
No Data...
Technical Data Sheet
| processability | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Shrinkage rate | ISO 294-4 | 1.5-2.0 | % | |
| Spiral flow length | 21 | CM | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| tensile strength | ISO 527 | 55 | Mpa | |
| elongation | Break | ISO 527 | 140 | % |
| bending strength | ISO 178 | 73 | Mpa | |
| Bending modulus | ISO 178 | 1.0*103 | Mpa | |
| Charpy Notched Impact Strength | Notched | ISO 179(leA) | ≥80 | kJ/m² |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.82MPa | ISO 75f | 58 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | 23℃,24hr | ISO 62 | 1.28 | % |
| density | ISO 1183 | 1.09 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dielectric constant | 106HZ | IEC 60250 | 3.4 | |
| Dielectric loss | 106HZ,Tangent | IEC 60250 | 3.0*10-2 | |
| Volume resistivity | IEC 60093 | 1*1014 | Ω。m | |
| Dielectric strength | IEC 60243 | 30 | KV/m | |
| Arc resistance | IEC 61621 | -- | sec | |
| ash content | 0 | % | ||
| flame retardant performance | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | UL 94 | HB |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.