Thermoset Premi-Glas® 1268
0
- Properties:Fillersglass fiber reinforced materials
- Usages:Metal substitution
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
density | 1.74 g/cm³ | ||
Shrinkage rate | 0.080 % | ||
Water absorption rate | ISO62 | 0.10 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Poisson's ratio | 0.35 | ||
Tensile stress | Break | ISO527-2 | 37.0 MPa |
Flexural modulus | ISO178 | 9200 MPa | |
Bending stress | ISO178 | 82.0 MPa | |
Tensile modulus | ISO527-2 | 10000 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
ISO180 | 10 kJ/m² |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
ISO75-2/A | >270 °C | ||
Glass Transition Temperature | ASTMD4065 | 177 °C | |
2.5E-05 cm/cm/°C | |||
3.5E-05 cm/cm/°C | |||
thermal conductivity | 0.48 W/m/K |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.
Contact Us
Get App
Top