PA6 LUVOCOM® 3/CF/30 VP
0
- Properties:Fillercarbon fiber reinforced material30%filler by weight
- Usages:Applications in profilesrollershandlesengineering accessoriestextile applicationsand automotive fields
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
Water absorption rate | <1.0 % | ||
density | ISO1183 | 1.28 g/cm³ | |
Shrinkage rate | DIN16901 | 0.10到0.30 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile stress | Break | ISO527-2 | 210 MPa |
Tensile strain | Yield | ISO527-2 | 3.0 % |
Flexural modulus | ISO178 | 15000 MPa | |
Bending stress | ISO178 | 315 MPa | |
Bending Strain | ISO178 | 3.0 % | |
Tensile modulus | ISO527-2 | 16000 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of simply supported beam without notch | ISO179/1fU | 45 kJ/m² | |
ISO179/1fU | 50 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Surface Resistivity | IEC60093 | <1.0E+3 ohms | |
insulation resistance | IEC60167 | <1.0E+3 ohms |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
ISO75-2/A | 210 °C | ||
Continuous use temperature | UL746B | 90.0 °C | |
Maximum operating temperature - SharrTerm | 210 °C | ||
DIN53752 | 2E-05 cm/cm/°C | ||
thermal conductivity | DIN52612 | 0.50 W/m/K |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.